Parcel Id: 07-11-31-7030-00290-0010 |
CONDITIONED SPACE: 2306 sqft |
GARAGE: 466 sqft |
OPENED PORCH (WITH ROOF) : 170 sqft |
Total Square Footage: 2942 sqft |
Block: 00290 |
Subdivision: 2154 - SECTION 30-ROYAL PALMS |
Job Phone: 831-383-2883 |
Location Address: 87 RAE DR |
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
Issue Date: 07/07/2023 |
NOC: RECORDED |
Applicant name: EDWARD LEE DAUBERT JR |
Owner: BRITE LIFE VENTURES LLC |
Address 7345 GREENBRIAR PARKWAY ORLANDO, FL 32819 |
Lot: 0010 |
Contracted Stated Job Value: ¤303,188.00 |
Job Description: single family residence |
Type: CN |
Type | Request Date | Result | Inspector |
ROW - STORMWATER FINAL | 02/08/2024 | APPROVED | PFLANAGAN |
Note: CORRECTIONS MADE At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved.--------------------------------------------------------------------------2/6/2024 - PREVIOUS INSPECTION NOTESTALKED TO DAN WITH BRITE HOMES AND TALK TO HIM ON WHAT NEEDS TO BE FIX FOR THE ROW FINAL TO PASS.1) NEED TO PICK UP ALL TRASH AND CONSTRUCTION DEBRIS FROM VACANT ACROSSED THE STREET. 2) SOD IN THE RIGHT OF WAY IN VACANT ALONG RADCLIFFE DRIVE NEEDS TTO MATCH EXISTING GRADE SUROUNDING IT. NOT FEEING YOU TODAY |
ROW - STORMWATER FINAL | 02/06/2024 | Disapproved - NO FEE | PFLANAGAN |
Note: TALKED TO DAN WITH BRITE HOMES AND TALK TO HIM ON WHAT NEEDS TO BE FIX FOR THE ROW FINAL TO PASS.1) NEED TO PICK UP ALL TRASH AND CONSTRUCTION DEBRIS FROM VACANT ACROSSED THE STREET. 2) SOD IN THE RIGHT OF WAY IN VACANT ALONG RADCLIFFE DRIVE NEEDS TTO MATCH EXISTING GRADE SUROUNDING IT. NOT FEEING YOU TODAY |
U -UTILITY RESIDENTIAL FINAL | 02/05/2024 | FINAL APPROVED | LFITZGERALD |
BLD - BUILDING FINAL | 02/05/2024 | FINAL APPROVED | JWALKER |
U-CROSS CONNECTION | 02/05/2024 | APPROVED - AS NOTED | LFITZGERALD |
Note: has potable irrigation with PVB installed-no cross connection |
ELECTRIC - EARLY POWER | 01/23/2024 | APPROVED | JWALKER |
Note: 1/22/2024 - PREVIOUS INSPECTION NOTESExterior front entry ceiling fixture outlet has not been safed off. |
ELECTRIC - EARLY POWER | 01/22/2024 | Disapproved - NO FEE | JWALKER |
Note: Exterior front entry ceiling fixture outlet has not been safed off. |
ROW - FINAL APRON (AFTER POUR) | 01/22/2024 | APPROVED | PFLANAGAN |
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. |
ROW - FINAL SURVEY (OFFICE USE ONLY) | 01/22/2024 | APPROVED | PFLANAGAN |
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. |
FIELD SURVEY | 01/22/2024 | APPROVED | PFLANAGAN |
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. |
ROW- PRE-APRON (PRE-POUR) | 12/12/2023 | APPROVED | PFLANAGAN |
Note: IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDSAt the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. |
U - SEWER TIE IN | 12/01/2023 | APPROVED | MGIBSON |
GRAVITY SEWER TEST | 12/01/2023 | APPROVED | MGIBSON |
INSULATION | 11/15/2023 | APPROVED | JWALKER |
Note: Inspector Notes from Inspection 242011/13/23 Form the list below only the nail plates at the water lines have been corrected Please have the rest of the items listed corrected at Insulation to avoid further fees. 11/9/2023 - PREVIOUS INSPECTION NOTES11/9/23 Items 1, 2, 4 and 5 listed below have not been corrected.11/7/2023 - PREVIOUS INSPECTION NOTES1. Install nail plates at the water heater pipes and the dryer duct. Top plates.2. Dryer duct snap locks and seams need to be sealed.3. Top chord furring strip/ fire blocking needs to be finished. Location top left side wall at the front door area.4. Flex duct going into the distribution box above the AHU closet is not installed and sealed properly.5. Several of the flex ducts leading into the registers are not making a smooth transition and taking a 90 degree turn. This will restrict air flow. Support the duct to allow for a smooth transition. |
PEP TANK INSTALLATION REQUEST | 11/15/2023 | APPROVED | BVITALE |
ALL ROUGH | 11/13/2023 | APPROVED - AS NOTED | JWALKER |
Note: 11/13/23 Form the list below only the nail plates at the water lines have been corrected Please have the rest of the items listed corrected at Insulation to avoid further fees. 11/9/2023 - PREVIOUS INSPECTION NOTES11/9/23 Items 1, 2, 4 and 5 listed below have not been corrected.11/7/2023 - PREVIOUS INSPECTION NOTES1. Install nail plates at the water heater pipes and the dryer duct. Top plates.2. Dryer duct snap locks and seams need to be sealed.3. Top chord furring strip/ fire blocking needs to be finished. Location top left side wall at the front door area.4. Flex duct going into the distribution box above the AHU closet is not installed and sealed properly.5. Several of the flex ducts leading into the registers are not making a smooth transition and taking a 90 degree turn. This will restrict air flow. Support the duct to allow for a smooth transition. |
ALL ROUGH | 11/09/2023 | Disapproved -FEE REQUIRED | JWALKER |
Note: 11/9/23 Items 1, 2, 4 and 5 listed below have not been corrected.11/7/2023 - PREVIOUS INSPECTION NOTES1. Install nail plates at the water heater pipes and the dryer duct. Top plates.2. Dryer duct snap locks and seams need to be sealed.3. Top chord furring strip/ fire blocking needs to be finished. Location top left side wall at the front door area.4. Flex duct going into the distribution box above the AHU closet is not installed and sealed properly.5. Several of the flex ducts leading into the registers are not making a smooth transition and taking a 90 degree turn. This will restrict air flow. Support the duct to allow for a smooth transition. |
ALL ROUGH | 11/07/2023 | Disapproved - NO FEE | JWALKER |
Note: 1. Install nail plates at the water heater pipes and the dryer duct. Top plates.2. Dryer duct snap locks and seams need to be sealed.3. Top chord furring strip/ fire blocking needs to be finished. Location top left side wall at the front door area.4. Flex duct going into the distribution box above the AHU closet is not installed and sealed properly.5. Several of the flex ducts leading into the registers are not making a smooth transition and taking a 90 degree turn. This will restrict air flow. Support the duct to allow for a smooth transition. |
LATH/BRICK/ WATER BARRIER | 11/01/2023 | APPROVED | JWALKER |
Note: Inspector Notes from Inspection 24601. Truss TO2T missing engineering, web near the rear of the building, Marked the engineering drawing for location.2. Truss T28 bottom chord repair needs 2x on each side of the repair. Check for corrections at all rough |
WALL SHEATHING | 10/06/2023 | APPROVED | JWALKER |
ROOF SHEATHING / BRACES/TIES/DOWN CELL | 10/06/2023 | APPROVED - AS NOTED | JWALKER |
Note: 1. Truss TO2T missing engineering, web near the rear of the building, Marked the engineering drawing for location.2. Truss T28 bottom chord repair needs 2x on each side of the repair. Check for corrections at all rough |
ROOF VALLEY & METAL | 10/06/2023 | APPROVED | JWALKER |
ELECTRIC-TUG | 09/26/2023 | APPROVED | JWALKER |
TIE BEAM / LINTEL | 09/21/2023 | APPROVED | JWALKER |
FOUND SURVEY APPROVED (OFFICE) | 09/18/2023 | APPROVED | AMOBLEY |
MONOLITHIC SLAB | 09/11/2023 | APPROVED | RSIMS |
Note: 9/8/2023 - PREVIOUS INSPECTION NOTES9/8/23Heavy rains have caused soil washout into the footing, rear left garage area. 9/7/2023 - PREVIOUS INSPECTION NOTES9/7/23 Slab depth has not been corrected. 9/6/2023 - PREVIOUS INSPECTION NOTES1. UFER ground has not been installed.2. Slab depth is to be a minimum of 3 1/2". Test lines have been left in place. Remove excess soil , tamp and reinstall string lines.3. The recessed shower area is missing 1 #5 rebar see detail F7 |
MONOLITHIC SLAB | 09/08/2023 | Disapproved - NO FEE | JWALKER |
Note: 9/8/23Heavy rains have caused soil washout into the footing, rear left garage area. 9/7/2023 - PREVIOUS INSPECTION NOTES9/7/23 Slab depth has not been corrected. 9/6/2023 - PREVIOUS INSPECTION NOTES1. UFER ground has not been installed.2. Slab depth is to be a minimum of 3 1/2". Test lines have been left in place. Remove excess soil , tamp and reinstall string lines.3. The recessed shower area is missing 1 #5 rebar see detail F7 |
MONOLITHIC SLAB | 09/07/2023 | Disapproved -FEE REQUIRED | JWALKER |
Note: 9/7/23 Slab depth has not been corrected. 9/6/2023 - PREVIOUS INSPECTION NOTES1. UFER ground has not been installed.2. Slab depth is to be a minimum of 3 1/2". Test lines have been left in place. Remove excess soil , tamp and reinstall string lines.3. The recessed shower area is missing 1 #5 rebar see detail F7 |
MONOLITHIC SLAB | 09/06/2023 | Disapproved - NO FEE | JWALKER |
Note: 1. UFER ground has not been installed.2. Slab depth is to be a minimum of 3 1/2". Test lines have been left in place. Remove excess soil , tamp and reinstall string lines.3. The recessed shower area is missing 1 #5 rebar see detail F7 |
PLUMBING 1ST ROUGH UNDERGROUND | 09/01/2023 | APPROVED | MGIBSON |
WATER METER INSTALLATION REQUEST | 08/09/2023 | APPROVED | CBOWERMASTER |
Department | Status | Date In | Date Out |
BLD | COMPLETE | 10/05/2023 | 10/06/2023 |
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM |
BLD | COMPLETE | 10/02/2023 | 10/03/2023 |
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM |
ENGIN1 | COMPLETE | 09/18/2023 | 09/18/2023 |
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM |
ZON | COMPLETE | 09/18/2023 | 09/18/2023 |
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM |
BLD | COMPLETE | 07/14/2023 | 07/17/2023 |
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM |
ZON | COMPLETE | 06/27/2023 | 06/27/2023 |
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM |
BADMIN | INFORMATION | 06/27/2023 | 06/27/2023 |
Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COMYour comment indicates you are submitting an elevation plan however you uploaded what apepars to be a full set of plans. Please upload only the plan sheet/document you would like to be reviewed by zoning. If all plan sheets are re-uploaded, this will receive another full review by all departments. |
ZON | HOLD | 05/15/2023 | 05/15/2023 |
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COMSide elevation page missing |
SW1 | COMPLETE | 05/15/2023 | 05/23/2023 |
Note: Released By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM |
ENGIN1 | COMPLETE | 05/15/2023 | 05/16/2023 |
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM |
ZON | HOLD | 04/28/2023 | 04/28/2023 |
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COMSide elevations page missing |
SW1 | HOLD | 04/28/2023 | 05/05/2023 |
Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COMALL PROPOSED ELEVATION ON RIGHT OF WAY LINE NEEDS TO BE EQUAL OR GREATER THAN CENTERLINE OF THE ROAD |
ENGIN1 | COMPLETE | 04/28/2023 | 05/01/2023 |
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM |
BLD | COMPLETE | 04/28/2023 | 05/02/2023 |
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM |
ENGIN1 | HOLD | 01/05/2023 | 01/05/2023 |
Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COMBenchmark elevation disagrees with CL of road elevations by .7' +/- |
BLD | COMPLETE | 12/12/2022 | 12/14/2022 |
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM |
CUSVC | COMPLETE | 12/12/2022 | 12/19/2022 |
Note: Released By: LISA ASBILL - - lasbill@palmcoastgov.com |
ELEC | COMPLETE | 12/12/2022 | 12/12/2022 |
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM |
ENGIN1 | COMPLETE | 12/12/2022 | 12/12/2022 |
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM |
LOCATE | COMPLETE | 12/12/2022 | 12/14/2022 |
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM |
MECH | COMPLETE | 12/12/2022 | 12/13/2022 |
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM |
SW1 | HOLD | 12/12/2022 | 12/19/2022 |
Note: Held By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COMThe tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side.Positive fall is considered to be 0.10 feet in 20 feet.The minimum fall from the rear property line to the front is 0.50 feet. |
ZON | HOLD | 12/12/2022 | 12/14/2022 |
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COMSide elevations page missing |
SWALE | COMPLETE | 12/12/2022 | 05/18/2023 |
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM |